- For 1/2-inch condenser microphone calibration
- IEC 60942:2003 Class1/ANSI S1.40-1984.
- Output sound level: at 94dB and 114dB.
Professional Sound Analyzer Back
聲級計及分析儀 (一型), IEC61672 type 1 Sound Level Meter, 1/1 Octave, 1/3 Octave (Optional), LEQ, Ln, Lmax, Lmin | |
Possible User |
LCSD Stadium Monitoring / Building Contractors / Occupation Safety / Events Organizer / HVAC & Air Contractors / S&V designer & consultancy |
![]()
|
BSWA308 是 IEC61672 - 1 型聲級計、分析儀。 它的設計針對聲學測量、環境雜訊監測、職業健康和安全檢測等應用。 可以做即時6.3Hz - 20KHz 倍頻程測試分析。 * Standard: IEC 61672-1:2013, IEC 60651:1979, IEC 60804:2000 * 1/1 Octave Band, 1/3 Octave Band analysis (optional) according to IEC 61260 1:2014 and ANSI S1.11 2004 * 8Hz~16kHz(1/1octave), 6.3Hz~20kHz(1/3octave) * 3Hz~20kHz.(Class1 microphone frequency range) * LEQ / L10 / L90 / Ln / Background noise / Peak / Lmax / Lmin / SPL sound curve etc. * Logger steps 0.1s to 24hrs * 22dB(A) to 136dB(A) * Data storage & PC analysis
|
聲級測量計 (2型), IEC61672 type 2 Sound Level Meter, (1/1 Octave), LEQ, Ln, Lmax, Lmin | |
Possible User |
HVAC Contractors / Chiller, Compressor or Refrigeration Contractors / Lift Contractors / Factories |
|
BSWA309 是IEC61672 - 2 型聲級計、分析儀。 它的設計針對聲學測量、環境雜訊監測、職業健康和安全檢測等應用。 可以做即時20Hz - 12.5KHz 倍頻程測試分析。 * Standard: IEC 61672-1:2013, IEC 60651:1979, IEC 60804:2000 * 1/1 Octave Band, 1/3 Octave Band analysis (optional) according to IEC 61260 1:2014 and ANSI S1.11 2004 * 20Hz~8kHz(1/1octave), 20Hz~12.5kHz(1/3octave) * 20Hz~12.5kHz.(Class2 microphone frequency range) * LEQ / L10 / L90 / Ln / Background noise / Peak / Lmax / Lmin / SPL sound curve etc. * Logger steps 0.1s to 24hrs * 25dB(A) to 136dB(A) * Data storage & PC analysis
|
Microphone Capsules |
MP231 Class 1 microphone free field |
Sensitivity |
-28 dB±3 dB (40 mV/Pa) |
|
microphone uses stainless steel as protection grid, which makes the microphone stronger and firmer. The MP231 conforms to IEC61672 Class 1 standard with a sensitivity of 40mv/Pa. The MP231 is perfect for its long-term stability. |
ICCP preamplifier |
MA231T ICCP preamplifier |
Frequency Response |
20 Hz ~ 200 kHz |
|
BSWA
MV series microphone preamplifiers
are used for externally-polarized
microphones.
It is suitable for accurate measurement of high sound intensity and can be powered by BSWA microphone power supply.
|
VSS058 |
VSS058 Low Frequency Volume Source |
Frequency Response |
50Hz~800Hz |
|
Features:
Application:
|
CA111 |
CA111 Sound Level Calibrator |
Standard |
IEC60942:2003 Class 1 |
|
Measure Range:
94 &
114 dB
Features: CA111 is a small sound source for calibration of measurement microphones, sound level meters and other sound measurement equipment. The calibrator can be used on 1/2-inch and 1/4-inch microphones with adapter. It conforms to IEC 60942:2003 Class 1, ANSI S1.40-1984 |
SoundTEK ST120 |
SoundTEK Sound Level Calibrator |
Standard |
IEC60942:2003 Class 1 |
|
Measure Range:
94 &
114 dB
Features:
|